Chem. Senses 27: 425-433,
2002
© Oxford University Press 2002
Sensory Detection of Glutaraldehyde in Drinking WaterEmergence of Sensitivity and Specific Anosmia
Chemosensory Perception Laboratory, Department of Surgery (Otolaryngology), University of California, San Diego, La Jolla, CA, USA
Correspondence to be sent to: William S. Cain, Chemosensory Perception Laboratory, Department of Surgery (Otolaryngology), University of California, San Diego, La Jolla, CA 92093-0957, USA. e-mail: wcain{at}ucsd.edu
| Abstract |
|---|
|
|
|---|
A study of 30 young adults (15 males, 15 females), screened to have normal olfaction, measured detection of the flavor of glutaraldehyde, a biocide that could occur in disinfected potable water. Over the range of interest, up to 100 p.p.m., flavor derived from olfactory stimulation. Higher concentrations would cause oral irritation. Fourteen subjects failed to detect the glutaraldehyde in the first of four sessions of testing. Eight of the 14 (seven males, one female) continued to exhibit the anosmia throughout testing. The other six (one male, five females) began to detect the material in session two and exhibited increasing sensitivity over sessions two to four. Their average sensitivity never reached that of the 16 subjects who evinced no anosmia and who also improved their performance over sessions. The combined group of 22 could detect 17 p.p.m. Less thorough testing would have yielded much higher values. Specific anosmia for this dialdehyde has precedence in anosmia for various monoaldehydes, most notably isobutyraldehyde. The positive influence of experience with a material on detection has been found previously, most intriguingly by Wysocki and colleagues, who showed that experience could differentially induce sensitivity to the odorant androstenone and suggested that the phenomenon might occur for other compounds. Glutaraldehyde appears to be one, perhaps of many.
| Introduction |
|---|
|
|
|---|
The volatile organic compound (VOC) glutaraldehyde (1,5-pentanedial; CAS No. 111-30-8) has broad-spectrum biocidal activity. In addition to its widespread application in cold sterilization of dental and medical instruments, such as endoscopes, glutaraldehyde can serve inter alia to disinfect potable water. This motivates interest in a drinking water quality standard for the material.
Standards for drinking water
Standards for the presence of materials in drinking water often specify
both primary maximum concentration levels, based principally upon criteria of
public health, and secondary maximum concentration levels, based upon odor,
taste and appearance. Primary standards normally derive from estimation of a
no-observable-adverse-effect level (NOAEL) for the most sensitive indicator of
toxicity of a material, calculation of total acceptable daily intake (ADI),
apportionment of estimated exposure via the routes food, water and air, and
computation of a maximum acceptable concentration per route from the ADI
(Greim, 2000
;
van Leeuwen, 2000
). Secondary
standards or guidelines normally derive from psychophysical testing for the
relevant perceptual attributes. Methodology for the testing varies, but
normally entails estimation of a concentration that panelists can just detect
or recognize. A secondary standard may indicate a maximum concentration at
some fraction or multiple of this quantity. The threshold odor number (TON),
with the value 1 set to the concentration of an operationally defined
threshold, serves often as a means to express a secondary standard. In the
USA, the Environmental Protection Agency (EPA) uses 3 TON as a secondary
standard (US EPA, 1979
). Since
the EPA chooses not to enforce the secondary standard, it exists principally
as a guideline.
Studies of animals exposed subchronically to concentrations of
glutaraldehyde in drinking water, up to 250 p.p.m. in dogs and 1000 p.p.m. in
rats and mice, uncovered no evidence of systemic toxicity to organs or tissue.
For concentrations
50 p.p.m. in the dogs and 250 p.p.m. in the rodents,
consumption of the water decreased, with compensatory and reversible renal
physiological effects (Hermansky et
al., 1995
). Most likely, a direct sensory property of the
material caused the decrease in consumption.
Chemosensory attributes of odor, chemesthesis and taste
Virtually all small VOCs (mol. wt < 200) have ability to evoke odor at
low concentrations and chemesthetic sensations at higher concentrations
(Cain and Cometto-Muñiz,
1995
). [A terminological note: inhaled as vapors, VOCs evoke odor
at low concentrations and what people often call pungency, but may
legitimately call irritation, at higher concentrations. Sipped in aqueous
solution, these VOCs evoke (olfactory-mediated) flavor, often called `taste',
at low concentrations and irritation at higher concentrations. Most small VOCs
will stimulate the gustatory system only at very high concentrations.] In
general, the more reactive a material, the smaller the gap between detection
of its odor (or flavor) and its irritation. For glutaraldehyde vapor, the gap
apparently lies somewhere below an order of magnitude
(Ballantyne and Jordan, 2001
).
A similar gap seems likely to apply to aqueous solutions.
If the aversion of the dogs and rodents came from sensory stimulation, most likely it came from irritation. If defined as an adverse health effect, sensory irritation could form the basis for a primary maximum contaminant level in drinking water. Somewhere below this level would lie concentrations relevant to a secondary maximum contaminant level based upon flavor. This study concerned specification of the concentrations over which humans can detect the flavor of glutaraldehyde. As straightforward as this mission sounds, it happens to have uncovered a relative blind-spot in the methodology used in chemosensory studies.
Methodology for measurement of absolute sensitivity
The literature on chemosensory detection contains some lessons about how to
obtain an accurate view of absolute sensitivity. In studies of olfactory
detection, subjects have shown gains of a few-fold in measured sensitivity
over repeated tests (Engen,
1960
; Rabin and Cain,
1986
; Cain and Gent,
1991
). The results supported the interpretation that a gain may
come from experience in the task rather than from an actual increment in
sensitivity. That experience may sharpen detection, irrespective of modality,
has long-standing precedent (Gibson,
1953
). Nevertheless, not all increments in measured sensitivity
need have the same origin. Some materials, most notably androstenone, may grow
differentially in detectability from a person's first experience to subsequent
experiences (Wysocki et al.,
1989
). In such cases, the number or availability of receptive
sites may actually increase from stimulation
(Wang et al., 1993
).
These instances could qualify as true induction of sensitivity rather than a
mere uncovering of true sensitivity.
Irrespective of the origin of effects of experience in any instance, tests
of chemosensory sensitivity rarely reckon with even their existence. Instead,
most testing relies on measurements taken in a single session. Such
measurements, quite common in the testing of contaminants in drinking water
(Young et al., 1994
),
often assess detection of a few concentrations just a few times, or even just
once. The American Society for Testing and Materials (ASTM) method E 679-79
for determination of odor threshold encourages presentation of just a single
trial for each of a few concentrations in a small sample of subjects
(ASTM, 1991
). For comparisons
of relative sensitivity across stimuli, single sets of measurements, though
not necessarily single presentations, may suffice. For specification of actual
absolute sensitivity, as for a potential contaminant, it seems at the very
least advisable to discover whether performance changes as measurement
proceeds. After all, people who drink tap water will do so regularly.
Just as single sets of measurements may underestimate sensitivity, they may
also inflate apparent individual differences
(Stevens and Dadarwala, 1993
).
Studies have reported individual differences as high as 100 000 to 1, with
reports of 1000 to 1 being routine (Brown
et al., 1968
; Punter,
1983
; Yoshida,
1984
; Takagi,
1987
,
1989
). Superficial measurement
with inevitably high random error may well play a part in the reported
scatter, though some other factors, such as greater age in some subjects in a
sample, may sometimes account for a fraction of the range
(Cain and Gent, 1991
;
Stevens and Dadarwala, 1993
).
In order to determine whether apparent individual differences represent true
differences, it is necessary to establish some stability in individual
performance. Repeated tests serve this goal, just as they reveal whether
experience with the stimulus counts.
Individual differences and specific anosmia
Individual differences of two kinds hold interest: those that lie within
the principal distribution among subjects and those that form another
distribution. A finding of two distributions can indicate existence of
specific anosmia to a material (Amoore,
1969b
, Brown et al.,
1968
; Stevens and O'Connell,
1991
; Baydar et al.,
1993
). For androstenone, for instance, a third to a half of
subjects, more males than females, fail to perceive it, with the basis for the
defect apparently genetic (Wysocki and
Beauchamp, 1984
; Wysocki and
Gilbert, 1989
). A similar difference between males and females
also exists for specific anosmia to the musk galaxolide
(Wysocki and Gilbert,
1989
).
Germane to the present study, Amoore et al. described a specific
anosmia to isobutyraldehyde in 36% of persons tested
(Amoore et al., 1976
).
The mode of the distribution for detection in the anosmics lay 260-fold above
that in sensitive persons. The authors concluded, from tests with isomers,
homologues and isosteric relatives of isobutyr-aldehyde, that the aldehyde
functional group, particularly with linkage to an iso- or sec-form and a
restriction to C3C5 in molecular size, favored
the anosmia.
Glutaraldehyde has received little attention with respect its properties as
an odorant. Its reported odor threshold equals 40 p.p.b.
(Ballantyne and Jordan, 2001
),
in the general vicinity of monoaldehydes of similar chain length (e.g.
n-butyraldehyde = 37 p.p.b.; n-valeraldehyde = 61 p.p.b.;
n-hexanal = 23 p.p.b.; Amoore
et al., 1976
). Its detectability in water has apparently
not been investigated.
| Materials and methods |
|---|
|
|
|---|
Subjects
Fifteen males and 15 females, aged 18-40 years (average 25) participated.
Test facilities
Testing took place in a well-ventilated flavor-laboratory at normal temperatures (21-23°C) and humidity (40-50% RH).
Test material
The test material comprised an analytically confirmed sample of glutaraldehyde (2%) provided by Union Carbide Corp. It was diluted to concentrations of interest with commercial drinking water (Arrowhead).
Procedure
Screening
Pilot work implied that the flavor of glutaraldehyde came from olfactory
stimulation at the concentrations of interest. Accordingly, screening of
subjects for chemosensory function entailed a test of olfaction. Subjects took
either the Connecticut Chemosensory Clinical Research Center (CCCRC) Test or
the University of Pennsylvania Smell Identification Test (UPSIT)
(Doty et al., 1984
;
Cain et al., 1988
).
Each has norms for normal and abnormal functioning. All subjects scored in the
normal range.
Flavor testing
Pilot work had indicated that subjects could virtually never detect
concentrations as low as 3 p.p.m. (v/v) and that most subjects, though not
all, could detect concentrations as high as 100 p.p.m.. Because concentrations
at or above 100 p.p.m. could cause oral irritation, either at the time of
testing or thereafter, 100 p.p.m. was the highest concentration tested (see
Appendix). The concentrations used in the main experiment ranged from 3.13 to
100 p.p.m. (3.4-110 mg/l), with six members that increased in concentration by
2-fold from one to the next.
Figure 1 shows the format of a data sheet for a test session and also illustrates the array laid out for a subject. A panel on the sheet corresponded to a tray with wells that contained 30 disposable plastic cups (30 ml capacity) of liquid and the numbers 1-10, as shown in the figure. For each of the 10 triads, one cup contained a concentration of the test material and two contained plain water (10 ml samples). An algorithm randomized the position of test material in a triad. The subject was blinded with respect to the position. A given tray held only one concentration of material, i. e. tray 6 held all concentrations of 3.13 p.p.m. (step 6 in Figure 1), tray 5 held all concentrations of 6.25 p.p.m. (step 5), tray 4 held all concentrations of 12.5 p.p.m. (step 4) and so on.
|
An experimental session began with tray 6. The subject sipped from the first cup of the first triad, expectorated the sample, rinsed with water and repeated the procedure with the second and third cups of the triad. During sampling, the subject needed to attend to which of the samples had the strongest flavor and at the end to choose one, guessing if necessary (three-alternative forced-choice). The subject also rated confidence in the choice, on the following scale: 1 = very low; 2 = low; 3 = moderate; 4 = high; 5 = very high. The subject then continued onto the second triad and repeated the same procedure.
When finished with the first two triads on tray 6, the subject moved on to tray 5 and sampled triads 1 and 2 in the same manner as for tray 6. This continued until the subject had sampled the first two triads of tray 1. By that time, the subject had scanned the entire range of concentrations, with two trials at each. After a 5 min break, the subject returned to tray 6 and sampled triads 3, 4, 5 and 6 in the manner described, moved on to tray 5 and so on. After another 5 min break, the subject returned to tray 6 again and sampled triads 7, 8, 9 and 10, moved on to tray 5 and so on.
A session lasted
90 min and yielded ten trials per concentration step.
Each subject participated in four such sessions. The median interval between
successive sessions for an individual was 5 days.
Pinched-nose testing
At the end of the four sessions, the most sensitive male and most sensitive
female served in four additional sessions that differed from the other
sessions in just one way: the subjects wore nose clips over their noses to
reduce olfactory stimulation. This served to check on whether non-olfactory as
well as olfactory stimulation guided detection.
| Results |
|---|
|
|
|---|
Females
Figure 2 shows how percentage correct detection, cumulated over four sessions and corrected for chance, varied with log concentration in p.p.m. (v/v) for the 15 female subjects individually. Fourteen came under the influence of the stimulus, i.e. showed increasing detection with concentration, though two others (F02 and F04) failed to reach even 50% correct detection. The subject (F15), who failed to come under the influence of the stimulus, yielded virtually a horizontal function.
|
Males
Figure 3 shows the psychometric functions for the males. For those subjects who came under the influence of the stimulus, males and females exhibited similar results. Strikingly, however, seven males (M03, M04, M10, M12, M13, M14 and M15) failed to come under the influence of the stimulus.
|
Effect of experience
Collection of data over four sessions permitted inspection of how experience influenced detection. Fourteen of the 30 subjects, eight males and six females, showed essentially no detection in session one (Figure 4). From session one to session two, however, six of these subjects (five females and one male) showed an abrupt increment in performance. For example, their detection of 100 p.p.m. increased more than 6-fold. For these subjects, the point of 50% detection went from indeterminacy in session one to 80 p.p.m. in session two and 48 p.p.m. by session four. The 16 subjects who exhibited detection in session one showed progressive improvement through their four sessions. The point of 50% detection progressed from 25 p.p.m. in session one to 13 p.p.m. in session four.
|
As Figure 5 illustrates, confidence tended to track performance. For example, in the crucial middle portions of the psychometric functions, between 25 and 75% correct, the gain in performance from the first to the fourth session for nonanosmics amounted to essentially one step in concentration (2:1) and differential confidence between correct and incorrect answers signaled the same gain.
|
Functions with the nose pinched
By showing how performance varied with the nose pinched and open in the most sensitive female and most sensitive male, Figure 6 demonstrates the olfactory-mediation of perception of the glutaraldehyde. With the nose pinched, performance fell to chance and rated differential confidence fell to zero.
|
| Discussion |
|---|
|
|
|---|
At what concentrations will persons with normal sensitivity to glutaraldehyde detect it in water? By session four, such subjects evinced detection significantly above chance at 6.25 p.p.m. [t(15) = 2.33, P < 0.05]. In session one, these subjects met the same criterion at 12.5 p.p.m. [t(15) = 2.28, P < 0.05]. For point of reference, had testing ceased after session one for the entire group of 30, the level would lie 12-fold higher, at 77 p.p.m. For all practical purposes, therefore, repeated testing, with its accompanying diagnostic possibilities, produced to an estimate of sensitivity an order of magnitude higher than single testing would have produced.
As indicated earlier, standards and guidelines may express maximum concentration of contaminants in water in terms of TON. A rule of TON = 3 applies relatively frequently, with threshold determined by ASTM method E679-79 or a variant. The ASTM method entails use of an ascending series and three-alternative forced-choice, with a single pass through the series per participant. If applied in this case, which we could do by scoring only the first trials at each concentration, 3 TON would equal 240 p.p.m. for the sample of 30 persons. The ASTM procedure would not have discerned the presence of anosmia, initial or otherwise. Subjects who fail to achieve detection of the highest concentration are assumed to have a detection point one-half concentration step above the highest.
Once aware that the sample does contain a reasonable number of anosmics, one can compute a threshold for the rest (number of subjects = 22). In the present tests, that equaled 17 p.p.m. in the fourth session and would give rise to a 3 TON of 51 p.p.m. (Figure 7). Irrespective of whether one would set the maximum allowable amount of glutaraldehyde in drinking water at a concentration as high as 50 p.p.m., the present comparison serves to illustrate that superficial testing will generally give the illusion that consumers will fail to detect levels they might readily detect.
|
If, as previously reported (Amoore
et al., 1976
), 36% of people have specific anosmia to
isobutyraldehyde, then that defect has few rivals in its frequency. Most
reported specific anosmias affect a much smaller percentage of persons
(Amoore, 1969a
). Subsequent to
screening for the specific anosmia, presumably in a single session per
subject, Amoore et al. empanelled 31 specific anosmics for further
studies of ten aldehydes and four nonaldehydes. The investigators used the
relative sizes of the anosmia among the aldehydes to draw conclusions about
structure and activity, as mentioned earlier. Although the present results by
themselves indicate nothing in detail about structureactivity, they do
suggest, along with the results of Amoore et al., a rather high
frequency of specific anosmia to aldehydes.
In a study of androstenone (Wysocki
et al., 1989
), it was found that specific anosmics given
daily exposure to the material had an induction of sensitivity, such that they
became osmic to it by their second test, a week after their first. Although
the gain occurred most dramatically from the first to the second test, it grew
until approximately the fourth test. The induction favored neither sex.
Anosmics given no experience between testing also showed progressive but less
dramatic gain out to four sessions. Testing entailed less exposure to the
material than in the present study, which makes it uncertain whether to
compare the present results to those given interpolated experience or those
just tested repeatedly. Others have confirmed that exposure to androstenone
can change anosmics to osmic status (Pause
et al., 1999
). Pause et al. gave just 1 min/day
over 1 week.
Data from earlier work (Wysocki et
al., 1989
) imply that the induction of sensitivity to
androstenone does not occur to all materials. Nevertheless, if the induction
occurred only when the organism begins with a specific anosmia, then we can
say that the question remains open. For most materials, specific anosmia
occurs infrequently enough that the matter would generally escape notice. A
study of whether induction would show up in physiological measures
(Wang et al., 1993
)
found induction of sensitivity to androstenone in mice specifically anosmic to
it and induction of sensitivity to isovaleric acid in mice specifically
anosmic to it. This led the authors to state: `Induction with two unrelated
odorants implies that olfactory induction is a general phenomenon that may
occur in a large fraction of the human population' (p. 998).
Subsequent behavioral experiments in mice and rats endorsed the claim of
generality irrespective of specific anosmia
(Voznessenskaya et al.,
1994
). This was also found to be the case in experiments in
humans, but so far only in an unusual instance with the substance pemenone,
somewhat of a simulant for androstenone. Exposure to it enhanced sensitivity
to androstenone, irrespective of osmic status to the pemenone or androstenone
(Stevens and O'Connell, 1995
).
The research of Wang et al. implicated the olfactory epithelium in
induced changes in sensitivity (Wang
et al., 1993
). Studies on transection of the olfactory
nerve have allowed the same interpretation
(Yee and Wysocki, 2001
).
More than a century ago, William James James, 1892) reminded us:
That `practice makes perfect' is notorious in the field of motor accomplishments. But motor accomplishments depend in part on sensory discrimination... In the purely sensorial field we have the well-known virtuosity displayed by the professional buyers and testers of goods. One man will distinguish by taste between the upper and lower half of a bottle of old Madeira. Another will recognize, by feeling the flour in a barrel, whether the wheat was grown in Iowa or Tennessee. The blind deaf-mute, Laura Bridgman, so improved her touch as to recognize, after a year's interval, the hand of a person who had once shaken hers; and her sister in misfortune, Julia Brace, is said to have been employed in the Hartford Asylum to sort the linen of its multitudinous inmates after it came from the wash, by her wonderfully educated sense of smell. (p. 252)
We have known little about the bases for these feats, relegating them to practice, as if this constituted an explanation. In olfaction, `practice' may actually have meaning in terms of changes in the peripheral nervous system. Experience or practice, in a more physiologically based sense, might account for some of the large individual differences reported in olfactory sensitivity. Some such differences might prove quite temporary. Only repeated measurements may reveal that aspect of individual differences.
| Appendix: on the definition of specific anosmia |
|---|
|
|
|---|
Concerns about irritation dictated use of a maximum concentration of 100 p.p.m. in the investigation. This left indeterminate the concentrations where less sensitive subjects might detect glutaraldehyde. Although we have treated the results of these people as indicative of specific anosmia, we have offered no definition of the condition.
Two definitions have existed historically. One, principally graphic, relies upon the presence of a bimodal distribution of sensitivity, with an antimode. This definition, as usually expressed, makes only an intuitive appeal to statistics in that it relies merely upon how the distributions look. A factor that constrains the range of concentrations, as in the present case, can obscure the separation between distributions. How can one know, then, that the subjects in the present investigation would not detect glutaraldehyde at 101 p.p.m. and thereby show no antimode? The answer lies in the slope of the psychometric function for the 22 subjects who could detect glutaraldehyde. For detection to increase from chance level to 50% required an increment of concentration of a factor of six, with only a 5% coefficient of variation. In the most optimistic of circumstances, i.e. if all eight of our `specific anosmics' began to detect glutaraldehyde just above 100 p.p.m., where average detection equaled 1.5%, their performance would not reach 50% until 600 p.p.m. Figure A1 shows the histogram that would result in that circumstance.
|
The other definition of specific anosmia relied upon statistics. When
Amoore failed to find bimodal distributions with antimodes for chemicals that
he thought should have revealed specific anosmia, he defined persons with
thresholds two standard deviations above the mean of apparent normals as
specific anosmics (Amoore,
1991
). Without converging evidence, this rule has no more to
recommend it than a rule based upon 1.5 or 2.5 SD, or any other number.
Nevertheless, the data in Figure
A1 would pass the rule of two standard deviations. Two standard
deviations above the mean for normals equals 209 p.p.m., lower than the 600
p.p.m. estimated by the most optimistic trajectory.
Finally, nothing requires that any analysis for specific anosmia use the point of 50% detection for comparisons. Equipped with psychometric functions for individual subjects, we could use any other criterion, 25% detection for instance. Two standard deviations above the mean for 25% detection equals 105 p.p.m., essentially at our highest test concentration. This would obviate extrapolation.
These various approaches to resolution of the difference between those with normal and those with poor sensitivity to glutaraldehyde depend upon gathering data for psychometric functions for individual subjects. Although time-consuming, the collection of the data necessary to allow consideration of stimulusresponse relationships has evident benefits.
| Acknowledgments |
|---|
Supported by Union Carbide Corp., a subsidiary of Dow Chemical Co. We thank Dr Bryan Ballantyne of Union Carbide Corp. for his technical advice and intellectual support. We thank Ms Karen Mor for dedicated work in the execution of the project.
| References |
|---|
|
|
|---|
American Society for Testing and Materials (ASTM) (1991) E679-79. Standard practice for determination of odor and taste thresholds by a forced-choice ascending concentration series method of limits. 1991 Annual Book of ASTM Standards. ASTM, Philadelphia, PA, Vol. 15.07, pp.34 -39.
Amoore, J.E. (1969a). A plan to identify most of the primary odors. In Pfaffmann, C. (ed.), Olfaction and Taste III. Rockefeller University Press, New York, pp.158 -171.
Amoore, J.E. (1969b) Specific anosmia: a clue to the olfactory code. Nature,214 , 1095-1098.
Amoore, J.E. (1991) Specific anosmia. In Getchell, T.V., Doty, R.L., Bartoshuk, L.M. and Snow, J.B., Jr (eds),Smell and Taste in Health and Disease . Raven Press, New York, pp. 655-664.
Amoore, J.E., Forrester, L.J. and Pelosi, P.
(1976) Specific anosmia to isobutyraldehyde: the malty
primary odor. Chem. Senses, 2,17
-25.
Ballantyne, B. and Jordan, S.L. (2001) Toxicological, medical and industrial hygiene aspects of glutaraldehyde with particular reference to its biocidal use in cold sterilization procedures. J. Appl. Toxicol., 21,131 -151.[Web of Science][Medline]
Baydar, A., Petrzilka, M. and Schott, M.-P.
(1993) Olfactory thresholds for androstenone and Galaxolide:
sensitivity, insensitivity and specific anosmia. Chem.
Senses, 18,661
-668.
Brown, K.S., MacLean, C.M. and Robinette, R.R. (1968) The distribution of the sensitivity to chemical odors in man. Hum. Biol., 40,456 -472.[Web of Science][Medline]
Cain, W.S. and Cometto-Muñiz, J.E. (1995) Irritation and odor as indicators of indoor pollution. In Seltzer, R.(ed.) Occupational Medicine: State of the Art Reviews. Hanley & Belfus, Philadelphia, PA, Vol.10 , pp. 1-13.
Cain, W.S. and Gent, J.F. (1991) Olfactory sensitivity: reliability, generality, and association with aging.J. Exp. Psychol. , 17,382 -391.
Cain, W.S., Gent, J.F., Goodspeed, R.B. and Leonard, G. (1988) Evaluation of olfactory dysfunction in the Connecticut Chemosensory Clinical Research Center.Laryngoscope , 98,83 -88.[Web of Science][Medline]
Doty, R.L., Shaman, P. and Dann, M. (1984) Development of the University of Pennsylvania Smell Identification Test: a standardized microencapsulated test of olfactory function. Physiol. Behav., 32,489 -502.[Medline]
Engen, T. (1960) The effect of practice and instruction on olfactory thresholds. Percept. Motor Skills, 10,195 -198.
Gescheider, G.A. (1997) Psychophysics: The Fundamentals, 3rd edn. Lawrence Erlbaum, Mahwah, NJ.
Gibson, E.J. (1953) Improvement in perceptual judgments as a function of controlled practice or training.Psychol. Bull. , 50,401 -431.
Greim, H. (2000) Scientific justification of setting limits. Food Chem. Toxicol.,38 (Suppl. 1),S107 -S110.
Hermansky, S.J., Ballantyne, B. and Fowler, E.H. (1995) Subchronic peroral toxicology of glutaraldehyde to the mouse, rat and dog. J. Am. Coll. Toxicol,15 , 261.
James, W. (1892) Psychology: Briefer Course. Henry Holt, New York.
Pause, B.M., Rogalski, K.P., Sojka, B. and Ferstl, R. (1999) Sensitivity to androstenone in female subjects is associated with an altered brain response to male body odor.Physiol. Behav. , 68,129 -137.[Medline]
Punter, P.H. (1983) Measurement of human
olfactory thresholds for several groups of structurally related
compounds. Chem. Senses, 7,215
-235.
Rabin, M.D. and Cain, W.S. (1986) Determinants of measured olfactory sensitivity. Percept. Psychophys., 39,281 -286.[Web of Science][Medline]
Stevens, D.A. and O'Connell, R.J. (1991)
Individual differences in thresholds and quality reports of human subjects
to various odors. Chem. Senses, 16,57
-67.
Stevens, D.A. and O'Connell, R.J. (1995)
Enhanced sensitivity to androstenone following regular exposure to
pemenone. Chem. Senses, 20,413
-419.
Stevens, J.C. and Dadarwala, A.D. (1993) Variability of olfactory threshold and its role in assessment of aging. Percept. Psychophys., 54,296 -302.[Web of Science][Medline]
Takagi, S.F. (1987) A standardized olfactometer in Japan: a review over ten years. Ann. NY Acad. Sci., 510,113 -118.[Web of Science][Medline]
Takagi, S.F. (1989) Human Olfaction. University of Tokyo Press, Tokyo.
US Environmental Protection Agency (EPA) (1979) National Secondary Drinking Water Regulations. Final Rule. Federal Register, 44, 140, 42195.
van Leeuwen, F.X.R. (2000) Safe drinking water: the toxicologist's approach. Food Chem. Toxicol.,38 (Suppl. 1),S51 -S58.[Web of Science][Medline]
Voznessenskaya, V.V., Parfyonova, V.M. and Wysocki, C.J. (1994) Induced olfactory sensitivity in rodents: a general phenomenon. Adv. Biosci.,93 , 399-406.
Wang, H.-W., Wysocki, C.J. and Gold, G.H.
(1993) Induction of olfactory receptor sensitivity in
mice. Science, 260,998
-1000.
Wysocki, C.J. and Beauchamp, G.K. (1984)
Ability to smell androstenone is genetically determined. Proc.
Natl Acad. Sci. USA, 81,4899
-4902.
Wysocki, C.J. and Gilbert, A.N. (1989) National Geographic Smell Survey: effects of age are heterogeneous.Ann. NY Acad. Sci. , 561,12 -28.[Web of Science][Medline]
Wysocki, C.J., Dorries, K.M. and Beauchamp, G.K.
(1989) Ability to perceive androstenone can be acquired by
ostensibly anosmic people. Proc. Natl Acad. Sci. USA,86
, 7976-7978.
Yee, K.K. and Wysocki, C.J. (2001) Odorant exposure increases olfactory sensitivity: olfactory epithelium is involved. Physiol. Behav., 72,705 -711.[Medline]
Yoshida, M. (1984) Correlation analysis of detection threshold data for `standard test' odors. Bull. Fac. Sci. Eng. Chuo Univ., 27,343 -353.
Young, W.F., Horth, H., Crane, R., Ogden, T. and Arnott, M. (1994) Taste and odor threshold concentrations of potential potable water contaminants. Water Res.,30 , 331-340.
Accepted February 13, 2002
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
K. M. Gonzalez, C. Peo, T. Livdahl, and L. M. Kennedy Experience-Induced Changes in Sugar Taste Discrimination Chem Senses, February 1, 2008; 33(2): 173 - 179. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Kobayashi, L. M. Kennedy, and B. P. Halpern Experience-Induced Changes in Taste Identification of Monosodium Glutamate (MSG) Are Reversible Chem Senses, May 1, 2006; 31(4): 301 - 306. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Diamond, P. Dalton, N. Doolittle, and P. A.S. Breslin Gender-specific Olfactory Sensitization: Hormonal and Cognitive Influences Chem Senses, January 1, 2005; 30(suppl_1): i224 - i225. [Full Text] [PDF] |
||||
![]() |
E. A. Bremner, J. D. Mainland, R. M. Khan, and N. Sobel The Prevalence of Androstenone Anosmia Chem Senses, June 1, 2003; 28(5): 423 - 432. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||








